Extreme
heat, humidity and fluctuating climatic conditions can shorten
the life of a ceiling system. USG's specially formulated Climaplus
ceiling panels resist high heat and humidity without visible sag
and are available in a range of performance options up to 100%
relative humidity and up to 40oC.
USG ceiling panels meet or exceed the minimum requirements of
BS8290 (1991) as defined as
a. Normal environments (max 25 ± 2°C / 65 ± 5% RH)
b. High humidity environments (max 25 ± 2°C / 90 ±
5% RH)
For
applications in extreme environmental conditions such as exterior
soffits, parking garages or swimming pools, products with 100%
RH/40oC are recommended. Install with Donn brand DX hot dipped
galvanised corrosion resistant grid.
For
applications with intermittent heating and cooling systems, uncontrolled
environmental conditions, natural ventilation systems or in humid
areas such as washrooms, kitchens or wet process areas, products
with 95%RH / 40oC or better are recommended.
For
applications with normal controlled environmental conditions,
products with 70% RH/ 29oC or better are suitable.